Industrial Electronic Weighing

DAT 500

The DAT 500 weight transmitter guarantees high performance and long-term reliability. It is equipped with several optionals: upload and download functions for programming with TESTER 1008, the connection can occur through the external converter and configuration and calibration can be done either from the front panel or from a PC.

Further Information

Technical Specifications

SKU: 13/2013

Technical Specifications

Regulatory compliance: EN61326-1, EN55011 and EN55014 for EMC; EN61010-1 for electrical security
Input sensitivity: 0.02 µV/ per count
Baud rate: 2400, 9600, 19200, 38400, 115200 adjustable
Filter: 0.1 ÷ 25 Hz adjustable
Peak Hold function: for dynamic measures
Display: 6 digit, red LED (7 segments), h 14 mm
Transmission distance: 15m (RS232C), 1000m (RS422 e RS485)
Trasducer input voltage: 5 V (max 6 load cells 350  Ohm)
Serial door: RS232C or RS422/RS485 with ASCII or Modbus RTU protocols
Linearity: <0.01% of full scale
Logic input: 2 optoisolated 24 V c.c. PNP (External voltage)
Logic output: 2 Solid-state relays, (maximum load 24 Vdc / 100 mA each)
Storage temperature: -20 ÷ +70 °C
Temperature range: -10 ÷ +50 °C
Tool voltage: 24 V c.c. ±15% - power 5 W
Set decimal: 0.0 ; 0.00 ; 0.000
Visible resolution: 60.000 divisions displayable on net weight
Bipolar optional output: only in voltage ±10V
Resolution: > 16.000.000 counts
Divisions value (adjustable): x1, x2, x5
Gain drift: <0.001% full scale/ °C
Dimensions and weight: 96 x 48 x 120 mm (L x H x D); 250 g
Measuring range: -0.5÷+3..5 mV/V (-3.9÷+3.9 mV/V optional)
Electrical connection: Terminal screw pass 5 mm
A/D Converter: 24 bit

Certifications

  • UL
  • GOST
  • EAC
  • OIML