Industrial Electronic Weighing

DAT 1400

The DAT 1400 weight transmitter has a capacitive keyboard and removable screw terminal blocks. It has the ability to integrate different options based on customer needs. For example, among future options there is the analog input which can be in tension or electrical and the RS485 connection to external 0I-BOX.

Further Information

Technical Specifications

Watch our tutorial

SKU: 06/2018

Technical Specifications

Temperature range: -10/+ 50 ° C (humidity max 85% no condensation)
Tool voltage: 12-24 Vdc ± 15% - Power consumption 5 W
Data storage: 64 Kbytes expandable up to 1024 Kbytes (optional)
Set decimal: 0.0 ; 0.00 ; 0.000; 0.0000
Microcontroller: ARM Cortex M0 + 32 bit 256KB Flash reprogrammable onboard from USB
Visible resolution: 999.999 displayable divisions on net weight
Temperature drift analog output: 0,001% FS / °C
Analog output linearity: < 0,02% FS
Resolution: > di 16.000.000 points
Frequency signal acquisition: 12 ÷ 1000 Hz
Gain drift: < 0.001% FS/ °C
Excitation voltage: 5 Vdc (max 8 -350 Ohm- load cells)
Measuring range: -3.9 ÷ +3.9 mV/V
Serial door: 1 USB device + 1 RS232C + 1 RS485/Fieldbus; ASCII or Modbus RTU protocol
A/D Converter: 24 bit
Divisions value (adjustable): x1, x2, x5, x10, x20, x50
Input sensitivity: 0.02 microV/div
Electrical connection: 5 mm terminal blocks, removable
Filter: Selectable 0.5 to 1000 Hz
Regulatory compliance: EN61000-6-2, EN61000-6-3 for EMC; EN61010-1 for Electrical Safety
Keyboard: capacitive, 4 keys
Analog optional output: optoisolated 16-Bit Voltage: 0 to 5/10 V (R min10 K Ohm), Current: 0/4 to 20 mA (R max 300 Ohm)
Display: 6 digit, 7-segment LED red, height 14mm
Peak Hold function: for dynamic measurements
Linearity: < 0.01% FS
Logic input: 2 opto-isolated 24 Vdc PNP (external power supply)
Logic output: 2 opto-isolated; MAX 24 Vdc/100 mA each
Storage temperature: -20/+70°C

Certifications

  • EAC
Tutorial 1 / 3

Tutorial 2 / 3

Tutorial 3 / 3