Industrial Electronic Weighing

MCT 1302

The MCT 1302 touch screen weight indicator is ideal for all types of weighing, in particular for static weighing and loading / unloading and multi-component dosing. It is easy to install and use and can be customized as needed. MCT 1302 has a multilingual menu, internal data memory of 64 Kbytes expandable up to 1024 Kbytes and simultaneous availability of Fieldbus and analogue output.

Further Inofrmation

Technical Specifications

SKU: 13/2018

Technical Specifications

  • Power supply:: 5 Vdc (max 8 -350 Ohm- load cells)
  • Measuring range:: -3.9 ÷ +3.9 mV/V
  • Input sensitivity:: 0.02 microV min
  • Linearity:: < 0.01% FS
  • Temperature drift:: < 0.001% FS/ °C
  • Display: : graphic LCD (240x128 pixel)
  • A/D converter:: 24 bit; internal resolution up to 16.000.000
  • Frequency signal acquisition:: 12 ÷ 1000 Hz
  • Displayable resolution:: 999.999 displayable divisions on net weight
  • Value divisions (selectable):: x1, x2, x5, x10, x20, x50; 4 decimal point
  • Filter:: selectable 0.1÷250 Hz
  • Keyboard:: 4 wires resistive touch screen
  • Power supply:: 18÷30 Vdc - Power consumption 5 W
  • Operating temperature:: -10/+ 50°C (humidity max 85% no condensation)
  • Storage temperature:: -20 ±+70°C
  • Logic outputs:: 6 opto-isolated; max 24 Vdc/100mA each
  • Logic inputs:: 6 optically isolated 24 Vdc PNP (external power supply)
  • Additional I/O:: up to 4 external modules with 4 in/8-out each (16 in/32 out, total) by independent RS485
  • Serial ports:: 1 USB device + 1 RS232C + 1 RS485/Fieldbus
  • Optional analogue output:: optoisolated 16-Bit Voltage: 0 to 5/10 V (R min10 K Ohm), Current: 0/4 to 20 mA (R max 300 Ohm)
  • Analog output calibration:: keyboard (touch screen)
  • Analog output linearity:: < 0,02% FS
  • Temperature drift analog output:: 0,001% FS/°C
  • Microcontroller:: ARM Cortex M0 + 32 bit 256KB Flash reprogrammable onboard from USB
  • Data storage:: 64 Kbytes expandable up to 1024 Kbytes
  • Regulatory Compliance:: EN61000-6-2, EN61000-6-3 for EMC; EN61010-1 for Electrical Safety, EN45501 for metrology
  • Electrical connections:: removable screw terminal blocks (3.81mm pitch)
  • Dimensions: : 150x95x26mm (LxWxH) including terminal blocks; 150x95x56mm (WxHxD) with fieldbus options; drilling t
  • Mounting type:: panel mount
  • Communication protocols:: ETHERNET 10/100 con protocolli TCP, MODUBUS/TCP, UDP, IP, ICMP, ARP; PROFINET; ETHERNET/IP; ETHERCAT