Industrial Electronic Weighing

C2G1

The Off Center C2G1 load cell is particularly suitable for the construction of industrial and electronic scales, piece counters and packaging machines. The C2G1 cell is able to weigh maintaining high precision and maximum reliability even with off-center load. The maximum dimensions of the applicable worktop are 300x300 mm.

Further Inofrmation

Technical Specifications

SKU: 37/2014

Technical Specifications

  • Rated load (RL):: 6 - 10 - 12 - 15 - 20 - 25 - 30 - 35 - 50 - 60 - 100 Kg
  • Non-Linearity:: ±0,015 % of R.O.
  • Repeatability:: ±0,02 % of R.O.
  • Creep (20 minutes):: ±0,02 % of R.L.
  • Safe overload:: 150 % of RL
  • Maximum overload:: 200 % of R.L.
  • Recommended input:: 5 ÷ 12 Vdc/Vac
  • Input resistance:: 420 +30/-20 Ohm
  • Output resistance:: 350 ±5 Ohm
  • Insulation resistance:: > 2000 M Ohm
  • Rated output (R.O.):: 2 ±0.2 mV/V
  • Zero balance:: < ±0.1 mV/V
  • Temperature range:: -10 ÷ +50 °C
  • Compensated temperature range:: -10 ÷ +50 °C
  • Temperature effect on zero balance:: ±0.004 % of R.O./°C
  • Temperature effect on output:: ±0.0012 % of output/°C
  • Max load deflection:: 0.17 ÷ 0.62 mm
  • Precision class:: 3000 n. OIML - 6000 n. OIML
  • Degree of protection:: IP64
  • Material:: Alluminum alloy
  • Electrical connection:: 4 conductors shielded cable; length 2 m

Certifications

  • OIML
  • EAC