C2G1

The Off Center C2G1 load cell is particularly suitable for the construction of industrial and electronic scales, piece counters and packaging machines. The C2G1 cell is able to weigh maintaining high precision and maximum reliability even with off-center load. The maximum dimensions of the applicable worktop are 300x300 mm.

Further Information

Technical Specifications

PVS: 37/2014

Download  

Technical Specifications

Rated load RL: 6, 10, 12, 15, 20, 25, 30, 35, 50 Kg
Repeatability: < ±0.02 % RO
Creep (20 minutes): < ±0.02 % RO
Full scale non-Linearity: ±0,015
Safe overload: 150 % RL
Ultimate overload: 200 % RL
Material: Alluminum alloy
Degree of protection: IP64
Accuracy class: 3000 OIML (6000 OIML optional)
Deflection: 0.17 ÷ 0.62 mm
Compensated Temperature: -10 ÷ +50 °C
Temperature range: -10 ÷ +50 °C
Temperature effect on zero balance: ±0.004 % RO/°C
Temperature effect on output: ±0.0012 % of load/°C
Rated output RO: 2.0 ±0.2 mV/V
Zero balance: < ±0.1 mV/V
Insulation resistance: >2000 MOhm
Input resistance: 400 ÷ 450 Ohm
Output resistance: 345 ÷ 355 Ohm
Recommended input: 5 ÷ 12 Vdc/Vac