Industrial Electronic Weighing

KOSD40

The BLH NOBEL KOSD40 load cell is suitable for force measurement application. The KOSD40 cell is easy to install and to maintain thanks to its cylindrical shape. The KOSD40 load cell is used for offshore platforms, cranes, tension measurement and level monitoring.

Further Information

Technical Specifications

SKU: 31/2015

Technical Specifications

*** -40° ÷ +100°C on demand:
Insulation resistance: > 4 G Ohm
** See the calibration chart of the load cell:
Output resistance: 350 ± 5 Ohm
* Referring to recommended loading point:
Input resistance: 350 ± 5 Ohm
ATEX certified versions for use in explosive atmospheres are available. II 1GD EEx ia IIC T4 Tamb = 60°C:
Recommended input: 10 Vdc/ac
Tolerance of shunt calibration values: ±1% of value**
Ultimate overload: 200% of R.L.
Safe sideload: 100% of R.L.
Safe overload: 100*% of R.L.
Electrical connection: 5m shielded four conductor cable 10, 20, 50kN 10m shielded four conductor cable 100, 200kN
Repeatability: 0.25% of R.O.
Temperature range: -40 to +80 (+100)°C***
Combined error: ±0.5% of R.O.
Ultimate sideload: 200% of R.L.
Rated load (R.L.): 10, 20, 50, 100, 200 kN
Temp. effect (-10°C to +50°C) on output: ±0.04% of output/°C
Temp. effect (-10° to +50°C) on zero balance: ±0.04% of R.O./°C
Maximum excitation: 18 Vdc/ac
Material: Stainless steel
Degree of protection: IP67
Zero balance: ±5% of R.O.
Rated output (R.O.): about 1 mV/V

Certifications

  • EAC
  • ATEX